Johnson Controls Software House C●CURE 9000

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.3
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: Johnson Controls
  • Equipment: Software House C●CURE 9000
  • Vulnerability: Use of Weak Credentials

2. RISK EVALUATION

Successful exploitations of this vulnerability could allow an attacker to gain administrative access.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Johnson Controls products are affected:

  • Software House C●CURE 9000: Version 2.80 and prior

3.2 Vulnerability Overview

3.2.1 USE OF WEAK CREDENTIALS CWE-1391

Under certain circumstances the Software House C●CURE 9000 installer will utilize weak credentials.

CVE-2024-32759 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-32759. A base score of 7.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing, Commercial Facilities, Government Facilities, Transportation Systems, Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Ireland

3.4 RESEARCHER

Reid Wightman of Dragos reported this vulnerabili

[…]