National Instruments LabVIEW

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.4
  • ATTENTION: Low attack complexity
  • Vendor: National Instruments
  • Equipment: LabVIEW
  • Vulnerabilities: Out-of-Bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow a local attacker to disclose information and execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following National Instruments LabVIEW products are affected:

  • LabVIEW: Versions 24.1f0 and prior

3.2 Vulnerability Overview

3.2.1 OUT-OF-BOUNDS READ CWE-125

LabVIEW is vulnerable to an out-of-bounds read, which could allow a local attacker to execute arbitrary code on affected installations of LabVIEW. User interaction is required to exploit the vulnerabilities in that the user must open a malicious VI file.

CVE-2024-4079 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-4079. A base score of 8.4 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 IMPROPER RESTRICTION OF OPERATIONS WITHIN T

[…]