As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).
1. EXECUTIVE SUMMARY
- CVSS v3 9.8
- ATTENTION: Exploitable remotely/low attack complexity
- Vendor: Siemens
- Equipment: Insights Hub Private Cloud
- Vulnerabilities: Improper Input Validation, Improper Isolation or Compartmentalization
2. RISK EVALUATION
Successful exploitation of these vulnerabilities could allow an attacker to perform arbitrary code execution, disclose information, or lead to a denial-of-service condition.
3. TECHNICAL DETAILS
3.1 AFFECTED PRODUCTS
Siemens reports that the following products are affected:
- Siemens Insights Hub Private Cloud: All versions
3.2 VULNERABILITY OVERVIEW
3.2.1 IMPROPER INPUT VALIDATION CWE-20
A security issue was discovered in ingress-nginx https://github.com/kubernetes/ingress-nginx where the auth-tls-match-cn Ingress annotation can be used to inject configuration into nginx. This can lead to arbitrary code execution in the context of the ingress-nginx controller and disclosure of Secrets accessible to th
[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.