Siemens OPC UA Implementation in SINUMERIK ONE and SINUMERIK MC

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global).

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINUMERIK MC, SINUMERIK ONE
  • Vulnerability: Integer Overflow or Wraparound

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • SINUMERIK MC: All versions prior to V1.22
  • SINUMERIK ONE: All versions prior to V6.22

3.2 Vulnerability Overview

3.2.1 INTEGER OVERFLOW OR WRAPAROUND CWE-190

The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial-of-service condition by sending a specially crafted certificate.

CVE-2023-28831 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Multiple
  • COUNTRIES/AREAS DEPLOYED:[…]
    Content was cut in order to protect the source.Please visit the source for the rest of the article.