Siemens SIDIS Prime

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SIDIS Prime
  • Vulnerabilities: Use of Insufficiently Random Values, NULL Pointer Dereference, Infinite Loop

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an unauthenticated attacker with access to the network where SIDIS Prime is installed to reuse OPC UA client credentials, create a denial-of-service condition of the SIDIS Prime OPC UA client, or create a denial-of-service condition of the SIDIS Prime TLS service.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • SIDIS Prime: All versions prior to V4.0.400

3.2 Vulnerability Overview

3.2.1 USE OF INSUFFICIENTLY RANDOM VALUES CWE-330

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man-in-the-middle attackers to reuse encrypted user credentials sent over the network.

CVE-2019-19135 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).

A CVSS v4 score has also been calculated for <
[…]
Content was cut in order to protect the source.Please visit the source for the rest of the article.

This article has been indexed from All CISA Advisories